AALBORG_logo AALBORG ROTAMETERS

rotameters
RotaMeters & Mass Flowmeters
Download Specification & Instruction Sheets
    RotaMeters (variable area type flowmeters)
  • Single & Multiple Tube Flow Meters;
  • Brass, Stainless and PTFE Flow Merets ets..
  • Flow Meters are installaled vertically in lines Gases or Liquids to be monitored.

  • Mass Flow Meters and Controllers
  • Flow ranges from 10 sccm to 1000 sL/min N2;
  • Max pressure of 500 psig;
  • 0-5 VDC and 4-20mA Outputs;
  • Built-in tiltable LCD readout.

    Vortex Inline Flowmeter
    High accuracy: 0.5% of rate. Increased noise cancellation as a result of dual signal processing technology.
  • Fluid types: liquid, Gas, Steam
  • Pipe: 3/4" to 6"
  • Air flow range: 2.2 to 58123 SCFM
  • Outputs: 4-20 mA
Vortex Flow Meter
Vortex Flow Meter

BADGER_logo BADGER Meter Europa ELECTROMAGNETIC FLOW METERS

Badger Flowmeter
    Electromagnetic Flow Meters - sizes 1/4" up to 56".
  • 3 types of Sensors,  
  • Electrodes materials: Hastelloy C, Tantalum, Platin/Rhodium.
  • Liner materials : PTFE, Hard- and Soft-Rubber, Halar.
  • Accuracy: +0.25%
  • Flowrange: 0.03 - 10 m/sec.
  • Analog Output: 4-20 mA,   Pulses scalable and RS232.

FLS_logoFLS - FIP ELECTROMAGNETIC INSERTION FLOW SENSORS

Electromagnetic Insertion Flow Sensor
FLS Electromagnetic sensor
  • Suitable for liquids with suspended solids, for abrasive liquids and liquids at high temperature
  • Flow Rate Range: 0.3 to 8 m/s, Pipe size from 2" to 16"
  • Fittings for installation into all pipe materials
FlowX3 ULFUltra Low Flow Sensor
FLS_sensor
  • Compact ultra-low flow sensor type ULF for use with aggressive and solid-free liquids
  • Flow ranges : 1.5 to 100 l/h (0.0066 to 0.44 gpm)  /  6 to 250 l/h (0.0264 to 1.1 gpm)
  • Construction materials: POM or ECTFE (Halar®) wetted parts
PADDLEWHEEL FLOW SENSORS / SWITCHES
FLS_sensor
    Paddlewheel Insertion Flow Sensors / Switches / Electonic Systems
  • Flow Sensors / Switches for every kind of solid-free liquids.
  • Flow ranges: 0.15 m/s to 8 m/s; sizes from 0.5" to 24"
  • Electonic Systems convert signal from Flow Sensors into a display indication and 4...20mA for long distance transmission.


  • Hebrew Instructions
FLS_monitor

Abest ULTRASONIC TRANSIT TIME TECHNOLOGY

Clamp-on Flowmeter
Clamp-on flowmeter
Portable Flowmeter
Portable Flowmeter
    Fixed and Portable Transit Time Ultrasonic
    Flow Meters
  • Ultrasonic Clamp-on Flow meter are Non Penetrating Instruments
  • The instrument is tolerant of liquids with small amounts of gas / air bubbles or suspended solids.
  • Pipe type ultrasonic Flow Meter (Flange models)
  • Hand Held Flow Meter
  • Hand Held Flowmeter Features:
    • Flow: 0 to 32 metres per second
    • Accuracy: ±0.5% of measured value for Flow cell

    •        ±1% of measured value at rate > 0.2 m/Sec
             for Clamp-on transducers
    • Pipe Size: 25mm to 6000mm (1 to 240")
Standard pipe-section (Flange Flowmeter)
Flange models
Standard pipe-section (Flange Flowmeter)

KEM_logo KEM FLOW METERS: TURBINE, MICRO, GEAR/HELICAL, MASS (CORIOLIS)

Positive Displacement,Gear Flow Meters.
Turbine Flow Meters,
Flow Controllers and Monitors, for Control of industrial fluids. Ideally for: multi-viscosity fluids, aggressive fluids and fluids under high pressure.
Turbidity Meter (KPS) The turbidity sensor serves the optimizing of industrial production processe, fluid food, chemical and pharmaceutical fluids .
KEM

  • Measuring ranges: 4.5-3,000 kg/h
  • Repeatability: 0.1% of actual value
  • Linearity: ±0.5% of actual value
  • Pressure: max. 350 bar
  • Temperature: max. +125oC
Extended Ranges
  • Measuring ranges:60-60,000 kg/h
  • Process Temp.:-40°C to +180°C
  • Ambient Temp.:-40°C to +60°C

  • Pulsar_logo PULSAR Process Measurement OPEN CHANNEL- FLOW METER

    OCM
      Open Channel Flow Meter
    • Measurement and Control for a wide range of Flumes and Weirs.
    • High frequency transducer dB Mach3.
    • Display: 8 digit on-board totaliser; / 6 digit display of flowrate or head.
    • 3 or 5 control relays for control choices.

    FlowCERT
      FlowCERT - Flow Measurement system.

    • The most accurate Flow measurement system available.
    • Consists of a dedicated control unit and Pulsar’s "Speedy velocity sensor".
    • Accuracy and ease of operation.
    • Analoge output and RS485 digital communications.
    • Speedy is available either as a “wedge” sensor to be fitted to the
      bottom of a channel or pipe, or as a pipe sensor.

    Sitron_logo SITRON FLOW SWITCHES

    Thermal dispersion Flow Switches with Relay Output.
    The CF12AC and CF12DC are compact switches that control the flow of liquid or gas in pipes and ducts.
    Option: sanitary connections.
  • Fast response time
  • Optimal temperature compensation
  • Excellent for low flow sensitivity
  • Insensitive to dirt and most particles
  • Simple to install and low in cost
  • No moving parts, maintenance free reliability

  • Orange_logo ORANGE RESEARCH D.P. FLOW INSTRUMENTS

      Flow and Differential Pressure Instruments.
    • Gauges and Switches.
    • Pistons and Diaphragm sensors.
    • Differential Pressure Transmitters.
    • Explosion-proof instruments.

    • Selection Guide & Instruction Sheets
    How They Work- DP     How They Work - Flow
    ORANGE

    Kuebler_logoKUEBLER FLOW MONITORS

    FLOW Monitors
    Adjustable switching point for Alarm, lens for flow display,
    Can be mounted at any position.

    Pulsar_logo PULSAR Process Measurement INTEGRATOR

      Pulsar's Beltweigher Integrator is ideal for all belt weighing applications. Six relays assignable to control, totalisation or alarm functions, plus analogue and digital outputs (Modbus/Profibus).
    • Application: 1,2, or 4 cell scales up to 4.5mV/V sensitivity.
    • Accuracy: 0.1% of full scale
    • Max separation: 150m to belt scale, 300m speed sensor.
    • Inputs: load cell, speed sensor (pulse train up to 65KHz),
      5 digital inputs
    Integrator

    Belt-Way_logo Belt-Way Scales SOLIDS FLOW METERS

    Solids Flow Meters
    Continuous in-line weighing of dry bulk materials from powders to granules. Material Flows down a tube and strikes an impact plate that is supported by two single point suspension Load Cells.
    Impact
    Belt Scales
    Continuous in-line weighing system, features an easy to install modular design. State of the Art, in-motion weighing technology, outstanding accuracy. Control System provides: Analogue output, Pulses, Master totals, calibration.
    MUS

    Belt-Way_logoViking Scales

    KiloWate TP4 The KiloWate TP4 Measures the Electrical Energy used to lift material, subtracting the energy lost to friction, and translating the rest directly into Tons and Tons Per Hour. It works best on conveyors with a vertical lift where the loaded current exceeds the empty current by 20 percent or more (i.e. 12 amps vs. 10 amps).
    The electrical connections are hooked up to the motor leads any place between the motor and its starter. The KiloWate TP4 has the ability to monitor up to 4 Belts.

      04 July 2010

    MEGATRON - Excellence in customers service since 1972.